TestWork Automation Software on a Client PC to operate the Test System

Core Test Systems - High Quality with short Delivery Time

The globally increasing electrolysis capacity causes an ever-increasing need for testing capabilities for electrolysis components. You need timely solutions for your hydrogen-related applications? We offer you core test solutions with short delivery times!

Our range of standardized solutions includes test systems for PEMFCs and SOFCs, as well as for electrolyzers such as PEM/AEL and SOECs in the power range between 1 kW up to 200 kW. The core test systems have a proven state-of-the-art design with a comprehensive safety concept.

The information on this page will give you a concrete overview of our offer and help you find the most suitable product for your needs.

PEM Fuel Cell Testing

Application

PEM
Cells

PEM
Short Stacks

PEM
Full Stack

Electrochemical Impedance Spectroscopy

 
Resistance Measurement 
Driving Cycles​
Accelerated Stress Test
Polarization Curves
Flexible Operation Conditions


Please note that our standardized solutions are only available in limited quantities. For more information about availabilities and delivery dates please contact us anytime.

Fuel Cell Testing of PEM Cells - Evaluator C10-LT 100 W

Electrical Load100 A/ 6 V/ 100 W
Gas Flow Anode

0.02 to 2 Nl/min H2

Gas Flow Cathode

0.05 to 5 Nl/min Air

Gas Pressure Range1.1 to 4 bara
Dew Point Control Range35 °C to 90 ºC
OptionsElectrochemical Impedance Spectroscopy (EIS), Cyclic voltammetry (CYV)

 

Fuel Cell Testing of PEM Cells - Evaluator C50-LT 250 W

Electrical Load250 A/ 2 V/ 250 W
Gas Flow Anode

0.5 to 5 Nl/min H2
0.5 to 5 Nl/min N2

Gas Flow Cathode

0.2 to 20 Nl/min Air
0.05 to 5 Nl/min O2
0.1 to 10 Nl/min N2
0.05 to 5 Nl/min CO
mixture in N2

Gas Pressure Range1.1 to 4 bara
Dew Point Control Rangeambient to 90 ºC

 

Fuel Cell Testing of PEM Cells - Evaluator C1000-LT 3 kW

Electrical Load1,000 A/ 35 V/ 3 kW
Gas Flow Anode

0.5 to 50 Nl/min H2
0.5 to 50 Nl/min N2

Gas Flow Cathode

1.6 to 160 Nl/min Air/O2
1.6 to 160 Nl/min N2

Gas Pressure Range1.1 to 4 bara
Dew Point Control Range35 °C to 90 ºC

 

PEM Short Stack Testing - Evaluator S5-LT 10 kW

Electrical Load1,000 A/ 60 V/ 10 kW
Gas Flow Anode

4 to 400 Nl/min H2
3.2 to 320 Nl/min N2

Gas Flow Cathode

10 to 929 Nl/min Air
10 to 929 Nl/min N2

Gas Pressure Range1.1 to 4 bara
Dew Point Control Range35 °C to 90 ºC

 

Testing of PEM Short Stacks - Evaluator S5-LT 18 kW

Electrical Load1,000 A/ 35 V/ 18 kW
Gas Flow Anode

3.5 to 350 Nl/min H2
3.5 to 350 Nl/min N2

Gas Flow Cathode

11 to 1,100 Nl/min Air/O2
11 to 1,100 Nl/min N2

Gas Pressure Range1.1 to 4 bara
Dew Point Control Range35 °C to 90 ºC

SOFC Fuel Cells & SOEC Electrolyzer Testing

Application

Elektrolyzer
Single Cells

SOFC
Single Cells

SOFC
Stacks

Electrochemical Impedance Spectroscopy 
Cyclic Voltammetry  
Load Cycles​
Accelerated Stress Test
Polarization Curves
Flexible Operation Conditions


Please note that our standardized solutions are only available in limited quantities. For more information about availabilities and delivery date please contact us anytime.

SOFC & SOEC Single Cells Testing - Evaluator C50-HT -300/300 W

Electrical Source / Sink

-100 to 100 A
0 to 6 V (SOFC)
0 to 4 V (SOEC)
-300 to 300 W

Gas Flow Anode

0.01 to 1 Nl/min H
0.01 to 1 Nl/min CO
0.01 to 1 Nl/min N

Gas Flow Cathode

0.05 to 5 Nl/min Air / N2

Gas Pressure Range0.8 - 1.2 bara
Gas Operating Temperatureambient to 1,050 °C

SOFC & SOEC Single Cells & Short Stacks Testing - Evaluator C1000-HT -6/3.6 kW

Electrical Source / Sink

-400 to 360 A
0.5 to 10 V
-6 to 3.6 kW

Gas Flow Anode

0.16 to 16 Nl/min H
0.16 to 16 Nl/min CO
0.0416 to 4.16 Nl/min CH
0.16 to 16 Nl/min NH
0.16 to 16 Nl/min N
0.16 to 16 Nl/min CO

Gas Flow Cathode

0.5 to 50 Nl/min Air / N2

Gas Pressure Range1.1 - 2 bara
Gas Operating Temperatureambient to 900 °C

SOFC & SOEC Stack Testing - Evaluator S25-HT -90/15 kW

Oven Size (LxWxH)0.6 m x 0.6 m x 0.9 m
Electrical Source / Sink

-600 to 350 A 
10 to 150 V 
-90 to 18 kW

Gas Flow Anode
(TwFl: Twin Flow)

TwFl: 0.05 to 208 Nl/min H
TwFl: 0.1 to 450 Nl/min N
TwFl: 0.1 to 45 Nl/min CH
TwFl: 0.1 to 190 Nl/min CO
TwFl: 0.125 to 540 Nl/min H2O

Gas Flow Cathode


TwFl: 0.1 to 450 Nl/min Air
Gas Pressure Measurement Range

0 - 1.6 bara 
accuracy: ± 0.25 % FS

Gas Operating Temperatureambient to 900 °C

Electrolyzer Single Cell for PEM & Alkaline - Evaluator C50-EC

Electrical Source400 A/ 6 V/ 1,000 W
Gas Flow Cathode H20.06 to 6 Nl/min

Gas Flow Anode O2

0.03 to 3 Nl/min

Gas Pressure Range1.2 -30 bara
Conductivity Sensors

 0.2 – 20 µS/cm (PEM) 
1 – 2,000 mS/cm (Alkaline)

Electrolyzer Single Cell for PEM - Evaluator C1000-EC

Electrical Source100 A/ 10 V/ 1,000 W
Gas Flow Cathode H20.06 to 3 Nl/min

Gas Flow Anode O2

0.03 to 1.5 Nl/min

Gas Pressure Range

1.1 -30 bara

Conductivity Sensors

Sensor Measurement Range 0 - 600 mS

Contact us

You are looking for a test station available at short notice or need further information? Then send us your inquiry.

Europe

Germany

HORIBA FuelCon GmbH
Otto-von-Guericke-Allee 20
39179 Magdeburg-Barleben
Germany

T +49 39203 964 400

sales.hfc(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

United Kingdom

HORIBA UK Limited
Kyoto Close
Moulton Park
Northampton NN3 6FL
United Kingdom

T +44 1604 542 500

enquiries.uk(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

France

HORIBA FRANCE SAS
Longjumeau Office
16-18 rue du Canal
91165 Longjumeau Cedex
France

T +33 1 69 74 72 00

info-sci.fr(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Italy

HORIBA Italia Srl

Via Le Luca Gaurico 209
00143 Roma
Italy

T +39 6 51 59 22 1

carlo.vinci(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Austria

HORIBA (Austria) GmbH
Kaplanstrasse 5
A-3430 Tulln
Austria

T +43 2272 65225

thomas.dieberger(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Sweden

HORIBA Europe GmbH
Sweden Branch (Gothenburg)
Grimboasen 10 A
S-417 49 Gothenburg
Sweden

T +46 10 161 1500

sales.hs(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Benelux

HORIBA Europe GmbH
Branch Office Benelux
Science Park 5080
5692 EA  SON
Netherlands

T +31 40 2900 240

piet-hein.vandeven(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

America

United States of America & Mexico

HORIBA Instruments Incorporated
Ann Arbor Office
5900 Hines Drive
Ann Arbor Michigan 48108
USA

T +1 734 213 6555

sales-ats.us(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Brazil

TCA HORIBA
Avenida Luigi Papaiz, 239
Diadema, SP, 09931-610
Brasilien

T +55 11 4224 0200

sales-ats.br(at)horiba(dot)com

 


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

Asia

Japan

Horiba Ltd.
2 Miyanohigashi-cho, Kisshoin
601-8510 Minami-ku, Kyoto
Japan

T +81 75 313 8121

shogo.ishida(at)horiba(dot)com
teruhiko.ikeda(at)horiba(dot)com


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.

South Korea

HORIBA KOREA Ltd.

25, 94-Gil, Iljik-Ro, Manan-Gu,
13901 Anyang-Si, Gyeonggi-Do
South Korea

T +82 31 296 7911

yongho.choi(at)horiba(dot)com


Blindmap

Wenn Sie auf den Button "Google Maps aktivieren" klicken, stimmen Sie der Übermittlung Ihrer Daten an Google Maps zu. Google Maps nutzt diese Daten möglicherweise für Analyse- und Werbezwecke.

Detaillierte Informationen zum Umgang mit Nutzerdaten finden Sie in unserer Datenschutzerklärung.

India

HORIBA India Private Limited
246, Okhla Industrial Estate
Phase III
110 020 New Delhi
India

T +91 11 4669 5001

sunil.gage(at)horiba(dot)com

 


Blindmap

If you click on the "Activate Google Maps" button, you consent to your data being transmitted to Google Maps. Google Maps may use this data for analysis and advertising purposes.

You can find detailed information on handling user data in our privacy policy.