SMART-CVM Single Cell Voltage Monitoring

SMART-CVM for multi-Channel Voltage Monitoring of Fuel Cell Stacks and Batteries
The cell voltage monitoring enables the multi-channel voltage monitoring of fuel cell stacks and batteries. Therefore, HORIBA FuelCon uses a CVM from SMART Testsolutions.
Due to to the position near to the test item, the galvanic isolation, digital signal pre-processing, cascading as well as the CAN and TCP/IP interface, allow the SMART-CVM meet all typical test requirements. In addition, it can be used separately as a diagnostic tool for fuel cell systems.
| Type | SMART Testsolutions Type: MCM-IntelliProbe-U10 |
|---|---|
| Number of cells | customized, 2,790 cells possible |
| Voltage range | -1 V to +5 V or -3 V to +3 V |
| Resolution | 16 Bit |
| Accuracy | ± 0.1 % |
| Sampling rate | <100 ms (up to 1 ms per channel on request) |